Installation 4.4 CHF 1 Using an Oracle Database Domain (Oracle Only)

Note: You must have already installed the 64-bit version of the Oracle version 12.2.0.1 client (Administrator) on the  Liquent InSight Rendering server. The 32-bit client will not work with Liquent InSight Rendering.

The Test Connection button is no longer available in the installer. Before attempting to install Liquent InSight Rendering on any server, please ensure the server is able to connect to the Oracle database by connecting to the database via SQLPLUS.

Note: Due to a known Oracle issue, an "unable to connect" error can appear. Perform the following procedure to be able to connect.
  1. Select Start > Run. Type cmd and press Enter. 
  2. cd to the bin folder under the Oracle client installation path. 
  3. At the prompt, type: regsvr32 oraoledb12.dll and press Enter. Select OK for the acknowledgment pop up. 
  4. Type exit and press Enter to close the command prompt.